Journal Information
Vol. 93. Issue 1.
Pages 151-153 (01 January 2018)
Share
Share
Download PDF
More article options
Vol. 93. Issue 1.
Pages 151-153 (01 January 2018)
Open Access
Evaluation of nickel and cobalt release from mobile phone devices used in Brazil*
Visits
3459
Mariana de Figueiredo Silva Hafner1, Jessica Chia Sin Chen2, Rosana Lazzarini1
1 Dermatology clinic at Santa Casa de São Paulo – São Paulo (SP), Brazil.
2 Medical student of the School of Medical Sciences at Santa Casa de São Paulo – São Paulo (SP), Brazil.
This item has received

Under a Creative Commons license
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (1)
Tables (1)
Table 1. Results of nickel and cobalt release in 20 mobile devices of different brands available in the Brazilian market in 2016
Abstract

Nickel and cobalt are often responsible for metal-induced allergic contact dermatitis. With the increasing use of cell phones, we observed an increase in cases reports on telephone-related allergic contact dermatitis. The present study evaluated nickel and cobalt release from mobile phones used in Brazil. We evaluated devices of 6 brands and 20 different models using nickel and cobalt allergy spot tests. Of the 20 models, 64.7% tested positive for nickel, with 41.1% positive results for the charger input and 23.5% for other tested areas. None of them was positive for cobalt. Nickel release was more common in older models.

Keywords::
Nickel
Cell phones
Cobalt
Full Text

The use of mobile phones has increased exponentially in the last ten years. Data from the Brazilian Telecommunications Agency (Anatel) indicate that, in May 2016, Brazil recorded 255.23 million active mobile telephone lines.1 Currently, there are several models of mobile devices on the market, most of which contain metal. Therefore, the widespread use of cell phones has led to a situation in which metal cell phone parts may come into contact with the user’s ear and face for prolonged periods of time. Thus, cases of cell phone allergic contact dermatitis (ACD) have been described in the literature.

Nickel and cobalt are the agents commonly responsible for metal-induced ACDs. The concomitance of positive tests to these elements occurs most often by co-sensitization, that is, simultaneous exposure to materials that contain them.2 Nickel is found in everyday objects such as keys, buckles, and buttons. It is a common allergen, accounting for about 24.5% of the positive tests obtained at specialized clinics in Brazil.2 The first report of a nickel-induced ACD case caused by a cell phone was described in 2000. Since then, other cases have been reported.3

In 1994 the European Union Nickel Directive was created to reduce the maximum permissible concentration of the metal in products of direct and prolonged contact with the consumer’s skin.4 Since then, the prevalence of nickel ACD has decreased in some European countries.5,6 In 2009, the Directive was revised and applied to mobile phones.4

The objective of this study was to evaluate nickel and cobalt release from cellular devices used in a São Paulo, Brazil.

The devices were tested for nickel release using dimethylglyoxime (DMG) (Chemo Nickel Test™, Chemotechnique Diagnostics – Vellinge, Sweden), which detects the release of 0.5μg/cm2/week with sensitivity of 59% and specificity of 98%. Cobalt, in turn, was investigated using Chemo Cobalt Test™ (Chemo Cobalt Test™, Chemotechnique Diagnostics – Vellinge, Sweden), which detects free cobalt down to a limit of 8 ppm.7 The positivity of the tests is related to the minimum amount of metal required for triggering ACD in humans. In Brazil, only the nickel detection test is commercially available.

Using flexible cotton swabs, we applied DMG to all metal areas of the phones, which included camera, main button, side buttons, charger and earphone inputs, and sides.(Figure 1) After that, we cleaned the device with a dry cloth and repeated the procedure with nitroso R-salt. The test is considered positive when color changes occur (from white to pink, for nickel, and from yellow to red, for cobalt). In the absence of color change, the test is considered negative. Both tests evaluate whether there is metal release from the device and not whether they are present in the metal alloys.7

Figure 1.

Positive test for nickel release from mobile devices

(0.03MB).

The tests were performed on 17 models (20 devices) of six different brands. Of these, 11 (64.7%) tested positive for nickel, with 7 devices (41.1%) releasing the metal only from the charger input and 4 (23.5%) from other areas (earphone input, main button, side buttons, top edge, or camera). All tests for cobalt were negative. Table 1 contains the complete list of results.

Table 1.

Results of nickel and cobalt release in 20 mobile devices of different brands available in the Brazilian market in 2016

Brand  Model  Release date  Type of device  # of tested devices  # (%) of devices tested positive for nickel  # of areas tested positive for nickel  # (%) of devices tested positive for cobalt 
Apple  iPhone 4  2010  Smartphone   
  iPhone 5c  2013  Smartphone  1 (100%)  1 (charger input) 
  iPhone 5s  2013  Smartphone  1 (100%)  1 (charger input) 
  iPhone 6  2013  Smartphone  3 (100%)  1 (charger input) 
  iPhone 6s  2015  Smartphone  2 (100%)  1 (charger input) 
Samsung  Galaxy gran prime duos  2014  Smartphone  1 (100%)  1 (charger input) 
  Galaxy core 2 duos  2012  Smartphone   
  Galaxy E3  2012  Smartphone  1 (100%)  2 (charger and headphone input) 
  Galaxy S6  2015  Smartphone  1 (100%)  1 (charger input) 
  ACE  2012  Smartphone  1 (100%)  2 (charger and headphone input) 
  SGH J700i  2008  Flip phone  1 (100%)  3 (main button, side buttons, camera) 
LG  G3  2014  Smartphone  1 (100%)  1 (charger input) 
  L80  2014  Smartphone   
  L70  2014  Smartphone   
Motorola  G3  2015  Smartphone   
HTC  HD mini t5555  2010  Smartphone  1 (100%)  1 (top edge) 
Sony Ericsson  Xperia X10  2009  Smartphone   

Despite the efforts to control the release of allergens, some merketed phones release sufficient levels of nickel to induce ACD.6 In adults and children, it is important to suspect this diagnosis when the patient presents with eczema on the face, neck, hands, torso, and anterior aspect of the thighs.

Most of the cell phones tested in this study were smartphones, which are currently the most used models. Studies conducted in Europe showed that between 18% and 26% of the tested cell phones tested positive for nickel, with higher rates for non-smartphones.7 A study conducted in the United States found that 24 of 72 (33%) cell phones yielded positive results for nickel.8 Our study presented higher results than the aforementioned studies (64.7%). However, considering that a large part (41.1%) of the models analyzed in our study showed positive results only for the charger input (greater wear and tear and reduced user contact), only 23.5% would be related to a possible ACD induction, which would approximate our results to those found in the European studies. It is worth noting that the cell phones that tested positive for nickel in more than one area in our study are non-smartphone and older models.

The present study detected no cobalt release from the analyzed devices. The data on the subject are divergent among studies. A Danish study that surveyed 50 brand new devices showed no metal release. On the other hand, Aquino et al. analyzed used devices and obtained positive results.8,9

Cell phone accessories were not tested in our study because they do not remain in contact with the user’s skin no prolonged periods, ie exposure greater than 30 minutes of continuous or more than 1 hour total of discontinuous skin contact in a day. On the other hand, a recent study revealed through laboratory tests that frequent and short contacts are also capable of releasing sufficient quantities of nickel to cause skin reactions, although they consider that prolonged contact is still a major cause.10

As observed by Aquino et al. and also revealed by the present study, the finding of nickel in a small number of phone models cannot be extrapolated to the various other models.8 However, nickel release from some models, even in areas with little user exposure, should draw the attention of physicians, especially when the devices are handled by patients known to be allergic to metals.

Financial support: None.

Conflict of interest: None.

References
[1.]
Anatel.gov.br [Internet]. Agência Nacional de Telecomunicações. Telefonia Móvel. Acessos [ acesso 23 Jul 2016]. Disponível em: http://www.anatel.gov.br/dados/index.php/component/content/article?id=283
[2.]
Duarte I., Mendonça R., Korles K., Lazzarini R., Hafner R..
Nickel, chromium and cobalt: the prevalence of occupational and nonoccupational sensitization.
Contact Dermatitis, 75 (2016), pp. 78
[3.]
Pazzaglia M., Lucente P., Vincenzi C., Tosti A..
Contact dermatitis from nickel in mobile phone.
Contact Dermatitis, 42 (2000), pp. 362-363
[4.]
Thyssen J.P., Johansen J.D..
Mobile phones are now covered by the European Union Nickel Directive.
Contact Dermatitis, 61 (2009), pp. 56-57
[5.]
Schnuch A., Uter W..
Decrease in nickel allergy in Germany and regulatory interventions.
Contact Dermatitis, 49 (2003), pp. 107-108
[6.]
Jensen P., Johansen J.D., Zachariae C., Menné T., Thyssen J.P..
Excessive nickel release from mobile phones-a persistent cause of nickel allergy and dermatitis.
Contact Dermatitis, 65 (2011), pp. 354-358
[7.]
Fowler J.F..
Cobalt.
[8.]
Aquino M., Mucci T., Chong M., Lorton M.D., Fonacier L..
Mobile phones: potential sources of nickel and cobalt exposure for metal allergic patients.
Pediatr Allergy Immunol Pulmonol, 26 (2013), pp. 181-186
[9.]
Thyssen J.P., Menné T., Lidén C., Julander A., Jensen P., Jakobsen S.S., et al.
Cobalt release from implants and consumer items and characteristics of cobalt sensitized patients with dermatitis.
Contact Dermatitis, 66 (2012), pp. 113-122
[10.]
Erfani B., Lidén C., Midander K..
Short and frequent skin contact with nickel.
Contact Dermatitis, 73 (2015), pp. 222-230

Work performed at the Dermatology Clinic at Santa Casa de São Paulo – São Paulo (SP), Brazil.

Copyright © 2018. Anais Brasileiros de Dermatologia
Idiomas
Anais Brasileiros de Dermatologia
Article options
Tools
en pt
Cookies policy Política de cookies
To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here. Utilizamos cookies próprios e de terceiros para melhorar nossos serviços e mostrar publicidade relacionada às suas preferências, analisando seus hábitos de navegação. Se continuar a navegar, consideramos que aceita o seu uso. Você pode alterar a configuração ou obter mais informações aqui.